Discussion in "ARM Development" started by    mikemike    Sep 4, 2008.
Thu Sep 04 2008, 08:43 pm
#1
i would like to change projects in ads1.2 environment to keil one, i match the scatterload file, POSIX format,etc but i got no errors but 2 warnings.

src\Startup.s(176): warning: A1608W: MOV pc,<rn> instruction used, but BX <rn> is preferred
src\Startup.s(247): warning: A1608W: MOV pc,<rn> instruction used, but BX <rn> is preferred

i have already googleing that but not much information about it......... :mad


[ Edited Tue Sep 23 2008, 10:11 am ]
Thu Sep 25 2008, 03:01 pm
#2
someone help
Fri Sep 26 2008, 02:03 am
#3
this warning is permitted. I dont think you will have any problem running your code. I will still try to find out more about this.
Fri Sep 26 2008, 11:37 am
#4
if you are really concerned with these warnings...
just edit line 176 and 247 to 'bx' .